FaceLCD Hong Kong Limited
Tel: +8615818692944
E-mail: sales@facelcd.com
Address: 13F, Buiding B, Colorful Tech Park, Guanlan High tech park, Longhua Dist, Shenzhen,China ZIP code 518100
You are here: Home > Technology >
An SPI LCD display can be used in a small size product which is to display the values, icons and small menus for the small product. The critical question is: Does the processor have an SPI port? Whether the complete system can update the necessary content while it's carrying out its other functions.
When an embedded engineer is designing an instrument, handheld controls or small connected device, the first place to start should be the workload of the interface. Determine the elements that change on the screen, how fast users want the feedback and how much they can spare to process the display. Next select a module and check with typical software.

Use the most “busy” screen the device can display. A fluctuating temperature is one scenario that places a different requirement on the system, versus a continuously scrolling graph. Determine what areas will need to be updated at the same time and which will not, can stay unchanged.
FaceLCD features an 80 x 160-format, 0.96-inch IPS TFT LCD screen, which is specified with an SPI interface. A good trial for status information, when the available pixels are first tried against actual labels, symbols and viewing distance.
Don't go higher in resolution just because the picture of the following panel looks good in a photo. The greater the number of pixels, the more information can be stored in a given area of a screen, but also the more data will be required to change the entire screen. Select sufficient room for text that is easy to read and allow time for the host to do his or her job.

An interface label can be used to mask an important architectural difference. Many SPI display systems use the serial connection to convey commands and pixel data. A separate RGB interface is used for transmitting the image data while SPI is used for configuration of the controller in some RGB arrangements.
If a product is listed as both SPI and RGB, then the drawing level check is required. Query about the interface to transfer pixels in the given version, how the mode is chosen and what signals the host must supply. It is wrong to design the PCB based on the title only.
FaceLCD's 1.77-inch TFT LCD TN is quoted as being SPI/MCU interface with a 128 × 160 resolution. Always check the configuration that is quoted (driver IC, connection requirements etc.). A family description doesn't guarantee that all modes are exposed on the same module or that they are turned on automatically.

The quantity of pixel data is determined by the area that is being updated and the format of the pixels being transmitted. An advertised color ability of the controller is not in itself a definition of how many bits you need to send for each pixel. Check the documentation in the module where applicable about the accepted format.
Determine the payload for the busiest update and compare with the available bus time. The time for pixels is reduced by commands, software overhead, transaction gaps, and any other devices that use the bus. Nominal SPI clock does not guarantee the frame-rate in an application.
During review, focus on three quantities that are separate: the frequency of software changing the content; the time spent on transfer; and the time of the panel scanning the image it stores. They differ from one another but are related. Depending on the controller architecture, an unchanged screen might not need to be transmitted by the host again.
If one number changes, it may be necessary to repeatedly send an entire background, which wastes transfer time. If the controller is capable of updating the address-window, organise the software to only update the parts of the screen that are affected, instead of every change as a full-frame change.
Make sure you plan around the real graphics library/memory. Partial buffer can lower the amount of host memory required and multiple smaller transactions can add overhead. Consider the overall outcome, don't just assume that the smallest buffer and/or highest clock is the fastest.
Be sure to look at the page transitions as well. Even a design that changes a status value fairly easily can still lock up in the process of changing a full screen menu. Determine which types of transitions require immediate feedback and what would be easier to understand in the background or less animation to make the product better without altering the panel.
| Update Area | Pixels | Payload at 16 bpp |
| Full 128 × 160 screen | 20,480 | 40,960 bytes |
| 40 × 40 icon | 1,600 | 3,200 bytes |
| 80 × 20 value field | 1,600 | 3,200 bytes |
Learn the IC reference, sequence, reset requirements, pixel format and orientation settings of the proposed display.
FaceLCD's TFT LCD module size is 1.47-inch, 172×320, SPI interface. Its portrait proportions might be more appropriate to other size status windows, but the firmware needs to handle the module appropriately. For that matter, before finalizing the screen coordinates, confirm any controller memory offsets and supported rotation behavior.
Check solids, edge marking, small text and screen orientation. If the colors and/or the content is not correct or if it shifts, this is an issue of initialization or data ordering, not a faulty LCD. Don't forget to associate the tested initialization file with the approved revision of the module.

Verify signal levels, pin definitions, control lines and power supplies. Unless the supplied assembly includes regulation or voltage conversion, an FPC connected module should not be considered a development breakout board with built-in regulation or voltage conversion.
Compare the clock timing to the specification of the controller and the final layout of the PCB or cable. Where a short bench wiring is used, this setup might require further consideration when it is to be used in a handheld enclosure.
In battery products, measure the entire display set up at useful brightness levels. SPI is a description of communication and not necessarily low total power. Energy should also include backlight operation, controller state and the host's rendering activity. Check sleep and wake behavior with the intended application.

Simultaneously operate the display while the device is performing its sensing, communications and user input operations. Determine the response with the worst foreseeable combination (including page change and wake-up).
When asking for a sample recommendation, specify the host platform, content requirements, interface and mechanical requirements through FaceLCD's small display sourcing support. Don't just talk about diagonal size and appearance, but include the update scenario as well.
Make note of the following items used during approval: Module model, driver configuration, bus settings, graphics buffer arrangement, and application build. Compare substitutions with the reference. If the workload you seek is more than your transfer budget will allow, be sure to consider another interface or display architecture - don't just expect another SPI module to be able to get you over the transfer budget hump.
An appropriate SPI LCD display should not have too much content to display, and should not have too much work to update. Verify the Pixel path, calculate the transfer requirements and analyze the precise module to be used with the desired firmware. Allow responsiveness and power behavior when the entire device is functioning.
Q1. Are all displays that mention SPI, using SPI to send image data?
No. Other designs initialize via SPI and transfer pixels via other interface.
Q2. Is there a way to know the end result of the interface frame rate using the SPI clock?
But Pixel format, Update area, Software overhead, Bus sharing all have an impact on performance.
Q3. Is there a need for an entire framebuffer in the host for an SPI LCD?
Not necessarily. The amount of buffer required is dependent on the controller, graphics library and method of updates.
Q4. Is it possible to directly interface an FPC module on any development board?
Not automatically. Verify voltage, pin assignment, power and necessary connection equipment.
Q5. Will using SPI provide more battery life?
Measure under operating conditions: back light, display electronics and host activity.